Free shipping above $ 10.000,00

New Hertix Smart Kld - Radio Frequency Device

$1377.59 USD
$1239.66 USD

Shipping Methods
Shipping for zipcode:
Calculate
I don't know my zipcode
Our store
  • Innove Pilates - Rua Marian Osman. 1210, Foz do Iguaçu - Atendimento de Segunda à Sexta das 9:00 às 18:00

    Free

Aderencias e fibroses tardias Aparelho de Radiofrequencia Celulite Cicatriz de acne equipamento para estetica Estetica intima Flacidez Flacidez Cutanea Hertix Smart Kld Linhas de expressao perioculares Melhora do contorno corporal Radiofrequencia Rejuvenescimento intimo Rugas e linhas de expressao

Description

Hertix Smart is a device for aesthetics, a resistive radiofrequency device for facial, body and intimate aesthetic treatments. It is indicated for treatments such as sagging skin, acne scars, adhesions and late fibrosis, cellulite, wrinkles and expression lines, improvement of body contour and is an excellent resource for treating intimate aesthetics. Hertix Smart is a device that has interchangeable tips, 3 for the face, 4 for the body and 2 for intimate aesthetics. High-powered and easy-to-program equipment is the best on the market to enhance your treatments and deliver the results your patients desire.

 

Differentiators and Benefits

 

Intimate rejuvenation: 1 applicator pen and 2 exclusive and autoclavable tips (S and L) for treating intimate areas;

 

Hygienic: autoclavable intimate tips;

 

Interchangeable tips: dispersive tip, concentric bipolar S, concentric bipolar G, longitudinal bipolar, tripolar, tetrapolar and hexapolar;

 

Applicators: 2 applicators, one universal for fitting facial and body tips and the intimate tip applicator;

Frequencies: 640 KHz (superficial with low heating), 1200 kHz (intermediate heating, allows for body and facial treatments) and 2400KHz (deep, recommended for body treatments, such as modeling);

Practicality: ready-made protocols;

High power: 140 Watts.

Indications

 

Radiofrequency:

Skin sagging;

Acne scars;

Late adhesions and fibrosis;

Cellulite;

Wrinkles and expression lines;

Periocular expression lines;

Improvement of body contour;

Intimate aesthetics:

Skin sagging;

Intimate rejuvenation.

Physiological Effects

 

Energy effect: by feeding the tissue with electromagnetic energy, it facilitates chemical reactions, allowing greater movement between ions through the lipoprotein membrane and facilitating the transformation of ADP and ATP;

 

Thermal effect: with the movement of ions and their friction, caused by the variation in the frequency of the electromagnetic field, local hyperthermia is generated, which determines an increase in blood and lymphatic circulation, improvement in nutritional and oxygen supplies, stimulating the activity of endocellular respiration and the expulsion of toxic catabolites, including free radicals;

 

Neocollagenesis: by thermocontraction of collagen: induction of heating in biological tissues, through the rotational effect of water molecules caused by the electromagnetic field that causes an inflammatory process, repair and regeneration in response to immediate thermal injury.

 

Protocols

 

Intimate Rejuvenation:

Tip: 8 mm;

Frequency: 1200 Khz;

Time: 6 minutes;

Temperature: 39 to 41º C;

Conductive Medium: Neutral Gel;

Body - Tissue sagging in saddlebags:

Tip: concentric body;

Frequency: 1200 Khz;

Time: 10 minutes;

Temperature: 40 to 42º C;

Conductive Medium: Glycerin Gel;

Facial - Submental (double chin):

Tip: bipolar facial;

Frequency: 1200 KhzT;

Time: 8 minutes;

Temperature 39 to 42ºC;

Conductive Medium: Glycerin Gel.

Therapeutic Associations

 

Kavys Ultracavitation: ultracavitation is a high-intensity focused ultrasound that promotes adipocyte degradation, associated with Hertix Smart, the application of radiofrequency causes vasodilation, improving blood and lymphatic circulation, increasing collagen and elastin synthesis, treating tissue sagging. Ultracavitation and Radiofrequency are great allies in body treatments.

Sonophasys: combination of 1.1 or 3.3 MHz ultrasound with low and medium frequency electrical currents or independently, enables treatments that ensure precision and agility in the most effective results. Combined with Hertix Smart, they are excellent equipment for delivering satisfactory results to your patient.

Conservation

 

Cleaning the device:

 

To clean the external part of the device, use only a damp cloth, do not use abrasive materials and/or solvents;

Cleaning and Sterilization of Intimate Tips:

The intimate tips are autoclavable and must be cleaned and sanitized with water and mild detergent, removing any and all visible residue. Dry completely with an absorbent towel, apply 1% chlorhexidine solution and dry again. After finishing the cleaning and sanitization process, place the tips in an autoclave at a temperature of 134º C for 15 minutes;

Applicators and tips:

The body of the applicator and the tips can also be disinfected after each application, using a 1% aqueous solution of chlorhexidine (found in pharmacies that distribute hospital products) or a similar product for 2 minutes.

Contraindications

 

Pregnant women;

Patients with pacemakers or other implanted electrical devices;

Hearing aids (patients who use hearing aids must remove them to undergo treatment);

Tuberculosis;

Rheumatoid arthritis;

Fever;

On malignant tumors;

On dermatoses;

On fillers;

About metal implants;

About regions close to serious circulatory problems;

About regions with changes in sensitivity;

About the eyeball.

Additional Information

 

Small Concentric Bipolar Tip: The electromagnetic field is concentrated in the circular electrodes. It is ideal for treating small flat regions, such as the forehead, cheeks, chin, neck and chest;

Large Concentric Bipolar Tip: The electromagnetic field is concentrated in the circular electrodes. It is ideal for medium flat regions, such as the arm.;

Monopolar or Dispersive Tip: It has a dispersive electromagnetic field that allows for deeper reach. It is indicated for improving body contour, aiding in localized fat treatments. By choosing the frequency, it is possible to reach the target tissue that will be treated more precisely. It can be applied to the buttocks, thighs, abdomen, chin and also the arm;

Longitudinal Bipolar Tip: It has a bipolar field and has 2 spherical electrodes. The electric current passes from one point to another, forming a "U" shape. It is indicated for the following areas: orbicularis oculi, orbicularis oris, nasolabial fold and the contour of the face;

Tripolar Tip: It has 3 spherical electrodes. The electromagnetic field has a deep reach, but covers a smaller area when compared to the Hexapolar tip. It can be used on the buttocks, thighs, abdomen, arms and neck;

Tetrapolar Tip: It has 4 spherical electrodes and the electric current propagates through each of them. It has a deep reach and is ideal for treating flatter areas such as the abdomen, buttocks, thighs, arms and neck;

Hexapolar Tip: It has 6 spherical electrodes and the electric current passes through all of them. The electromagnetic field has a deeper reach and covers a larger propagation area. It can be used on the buttocks, thighs and abdomen;

15 mm Intimate Tip: The magnetic field is more comprehensive and superficial. For intimate rejuvenation in the external area;

Intimate Tip 8 mm: The electromagnetic energy is more punctual and deep. For intimate rejuvenation.

Included Items

 

01 Hertix Smart Device - KLD;

01 Large Concentric Bipolar Tip;

01 Small Concentric Bipolar Tip;

01 Dispersive Tip (Monopolar);

01 Longitudinal Bipolar Tip;

01 Tripolar Tip;

01 Tetrapolar Tip;

01 Hexapolar Tip;

01 Pen for intimate region;

02 Pen tips;

01 11x5cm silicone electrode;

01 Colorless gel for Dispersive Electrode;

01 Hertix dispersive cable;

01 Side B applicator support;

01 Black Power Cable PP 3x0.75mm, 2m (NBR/IEC) with lock;

01 Digital IR Thermometer;

01 Warranty Term.

The Glycerin Gel is not included with the equipment and is essential for the application of the therapy.

Optional Accessories

 

Sold separately:

Smart Line Rack - HLD.

Technical Specifications

 

Hertix Smart Kld - Radiofrequency Device;

Brand: KLD;

Model: TFH 1701;

Operating mode: continuous;

Frequency: 640, 1200 and 2400KHz;

RF applicators: dispersive, concentric and longitudinal bipolar, tripolar, tetrapolar, hexapolar and intimate;

Power: 140W;

Intensity: 350Wpp;

Applicators: monopolar, bipolar, tripolar, tetrapolar, hexapolar and intimate;

Dimensions: 26x35x13cm (WxDxH);

Weight: 6kg.

Technical Data

 

Brand: Kld Biosistemas

Model: RADIOFREQUENCY THF-1701

Warranty: 12 months

NCM: 90189099

Anvisa: 10245230024

GTIN/Bar Code: 7898971230020

Anvisa Observation: VALID

Anvisa Description: HERTIX SMART

Registration Expiration: VALID

Dimensions and Weights

 

Product:

36.0 cm x 48.0 cm x 44.0 cm (L x W x H)

Weight: 6.0 kg

Packaging:

40.0 cm x 50.0 cm x 50.0 cm (L x W x H)

Weight: 6.5 kg